Effectiveness of tuned mass damper system for steel frame building

Binh Pham, T. and Tu Nguyen, V. (2020) Effectiveness of tuned mass damper system for steel frame building. In: 23rd International Scientific Conference on Advance in Civil Engineering: Construction - The Formation of Living Environment, FORM 2020, 23 September 2020 through 26 September 2020.

Text
Effectiveness of tuned mass damper system for steel frame building..pdf

Download (1MB) | Preview

Abstract

The paper presents the analysis of using tuned mass damper system for reducing the response of structure subjected to lateral force, such as earthquake action. The assumed steel eight-story steel frame building is examined. The tuned mass damper system is modeled as 2 joint link in SAP2000, attached to top story of the building. The effect of tuned mass damper system for building under seismic excitation was evaluated by the results of maximum displacement and acceleration of the building. A sensitivity study was also performed to compare the structural response with different mass ratios. From the calculated results, discussions and conclusions are presented. © 2020 Published under licence by IOP Publishing Ltd.

Item Type: Conference or Workshop Item (Paper)
Divisions: Institutes > Institute of Techniques for Special Engineering
Identification Number: 10.1088/1757-899X/869/5/052075
Additional Information: Conference code: 161681. Language of original document: English. All Open Access, Bronze.